Compact Flowmeters has a polycarbonate housing that extends over the lightweight aluminum body providing superior durability. Its state of-the-art housing incorporates a white backdrop that allows accurate adjustments and reading of the flow setting. The contemporary design results in a smaller flowmeter that fits more easily into space-cramped wall rails. The flow control knobs are on the front of the flowmeter in clear sight of the clinician and marked by gas type for added safety. Available in both air and oxygen models.
Caution! U.S. Federal law restricts this device to sale by or on the order of a physician.
Model: 8MFA1XXXGas:
Oxygen
Flow Range:
0 – 15 l/min
Graduations:
0.5 (0 – 5) l/min
1.0 (5 – 15) l/min
Accuracy:
0 – 5 ± 0.25 l/min
6 – 15 ± 0.50 l/min
Model: 8MFA2XXXGas:
Air
Flow Range:
0 – 15 l/min
Graduations:
0.5 (0 – 5) l/min
1.0 (5 – 15) l/min
Accuracy:
0 – 5 ± 0.25 l/min
6 – 15 ± 0.50 l/min
Model: 8MFA4XXXGas:
Oxygen
Flow Range:
0 – 8 l/min
Graduations:
0.5 l/min
Accuracy:
0 – 8 ± 0.25 l/min
Manuals
- Flowmeter User Manual – English
- Flowmeter User Manual – Danish
- Flowmeter User Manual – Dutch
- Flowmeter User Manual – Finnish
- Flowmeter User Manual – French
- Flowmeter User Manual – German
- Flowmeter User Manual – Greek
- Flowmeter User Manual – Irish
- Flowmeter User Manual – Italian
- Flowmeter User Manual – Polish
- Flowmeter User Manual – Portuguese
- Flowmeter User Manual – Spanish
- Flowmeter User Manual – Swedish
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Precision Medical, Inc. warrants that the Medical Gas Flowmeter (the Product) will be free of defects in workmanship and/or material for the following period:
(a) Flow Tube and Housing Lifetime of the product
(b) Needle Valve Five (5) years from shipment
(c) All other parts of the Medical Gas Flowmeter not identified in (a) or (b) above One (1) year from shipment
Warranty does not cover breakage/abuse.
Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, lnc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense.
ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.
The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of that contract.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.
Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice.
Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.